Q: What should be the temperature of Footwear Dies/Mould during the PU Poring?
A: Dies/Mould Temperature should be 40-45 degree +- according to room temperature.
Q: What Should be the Release Output by the release gun through nozzle?
A: Release Output should be 8gm Per 10 Sec.
Q: What should we do if we face skin problem in dye?
A: We should increase the output of release 1 or 2 gram as per the situation.
Q: What should we do If Deposition appears in Dies/Mould during the poring?
A: In Case of deposition appears in Dies/Mould, we should reduce the output of release by 2 to 3 gram as per the situation.
Q: What should be regular Dies/Mould cleaning Cycle?
A: We should clean the dye every week by Dimethylformamide (DMF).
Q: What should be the temperature of Footwear Dies/Mould during the PU Poring?
A: Dies/Mould Temperature should be 50-55 degree + - according to room temperature.
Q: What Should be the Release Output by the release gun through nozzle?
A: Release Output should be 5-6gm Per 10 Sec.
Q: What should we do if we face skin problem in dies/Mould?
A: We should increase the output of release 1 or 2 gram as per the situation.
Q: What should we do If Deposition appears in dies/Mould during the poring?
A: In Case of deposition appears in dies/Mould, we should reduce the output of release by 1-2 gram as per the situation.
Q: What should be regular dies/Mould cleaning Cycle?
A: We should clean the dies/Mould every week by Dimethylformamide (DMF ).
Q: What should be the mixing time of pigment in polyol?
A: Mixing time should be 45 minutes to 1 Hour..
Q: What should be the ratio or qty of pigment to be mixed in polyol?
A: it should be 6-10 kgs as per the requirements.
Q: What should be the Air Pressure in Dosing Tank?
A: Air Pressure depends on the Tank Size, As [per the Tank Size we should set the air pressure.
Q: Can we adjust the qty of pigment during the poring process?
A: Yes, We can adjust the ratio of pigment as per the color requirement.
Q: If we face any issue of pigment output, What should we do?
A: We should check the density of pigment, it must be in liquid form.
We should check the pigment tank pump, there is possibility of filter jam in the pump. If it is we should clean the filter.